- Home
- Search Results
- Page 1 of 1
Search for: All records
-
Total Resources3
- Resource Type
-
0000000002010000
- More
- Availability
-
30
- Author / Contributor
- Filter by Author / Creator
-
-
Bean, Richard (3)
-
Fromme, Petra (3)
-
Koua, Faisal_H M (3)
-
Mancuso, Adrian P (3)
-
Sato, Tokushi (3)
-
Barty, Anton (2)
-
Bielecki, Johan (2)
-
Chapman, Henry N (2)
-
Doppler, Diandra (2)
-
Frank, Matthias (2)
-
Fromme, Raimund (2)
-
Kirkwood, Henry (2)
-
Letrun, Romain (2)
-
Mariani, Valerio (2)
-
Ourmazd, Abbas (2)
-
Pandey, Suraj (2)
-
Poudyal, Ishwor (2)
-
Ros, Alexandra (2)
-
Schmidt, Marius (2)
-
Schwander, Peter (2)
-
- Filter by Editor
-
-
& Spizer, S. M. (0)
-
& . Spizer, S. (0)
-
& Ahn, J. (0)
-
& Bateiha, S. (0)
-
& Bosch, N. (0)
-
& Brennan K. (0)
-
& Brennan, K. (0)
-
& Chen, B. (0)
-
& Chen, Bodong (0)
-
& Drown, S. (0)
-
& Ferretti, F. (0)
-
& Higgins, A. (0)
-
& J. Peters (0)
-
& Kali, Y. (0)
-
& Ruiz-Arias, P.M. (0)
-
& S. Spitzer (0)
-
& Sahin. I. (0)
-
& Spitzer, S. (0)
-
& Spitzer, S.M. (0)
-
(submitted - in Review for IEEE ICASSP-2024) (0)
-
-
Have feedback or suggestions for a way to improve these results?
!
Note: When clicking on a Digital Object Identifier (DOI) number, you will be taken to an external site maintained by the publisher.
Some full text articles may not yet be available without a charge during the embargo (administrative interval).
What is a DOI Number?
Some links on this page may take you to non-federal websites. Their policies may differ from this site.
-
Abstract Sample consumption for serial femtosecond crystallography (SFX) with X-ray free electron lasers (XFELs) remains a major limitation preventing broader use of this powerful technology in macromolecular crystallography. This drawback is exacerbated in the case of time-resolved (TR)-SFX experiments, where the amount of sample required per reaction time point is multiplied by the number of time points investigated. Thus, in order to reduce the limitation of sample consumption, here we demonstrate the implementation of segmented droplet generation in conjunction with a mix-and-inject approach for TR studies on NAD(P)H:quinone oxidoreductase 1 (NQO1). We present the design and application of mix-and-inject segmented droplet injectors for the Single Particles, Clusters, and Biomolecules & Serial Femtosecond Crystallography (SPB/SFX) instrument at the European XFEL (EuXFEL) with a synchronized droplet injection approach that allows liquid phase protein crystal injection. We carried out TR-crystallography experiments with this approach for a 305 ms and a 1190 ms time point in the reaction of NQO1 with its coenzyme NADH. With this successful TR-SFX approach, up to 97% of the sample has been conserved compared to continuous crystal suspension injection with a gas dynamic virtual nozzle. Furthermore, the obtained structural information for the reaction of NQO1 with NADH is an important part of the future elucidation of the reaction mechanism of this crucial therapeutic enzyme.more » « less
-
Pandey, Suraj; Calvey, George; Katz, Andrea M; Malla, Tek Narsingh; Koua, Faisal_H M; Martin-Garcia, Jose M; Poudyal, Ishwor; Yang, Jay-How; Vakili, Mohammad; Yefanov, Oleksandr; et al (, IUCrJ)Here, we illustrate what happens inside the catalytic cleft of an enzyme when substrate or ligand binds on single-millisecond timescales. The initial phase of the enzymatic cycle is observed with near-atomic resolution using the most advanced X-ray source currently available: the European XFEL (EuXFEL). The high repetition rate of the EuXFEL combined with our mix-and-inject technology enables the initial phase of ceftriaxone binding to theMycobacterium tuberculosisβ-lactamase to be followed using time-resolved crystallography in real time. It is shown how a diffusion coefficient in enzyme crystals can be derived directly from the X-ray data, enabling the determination of ligand and enzyme–ligand concentrations at any position in the crystal volume as a function of time. In addition, the structure of the irreversible inhibitor sulbactam bound to the enzyme at a 66 ms time delay after mixing is described. This demonstrates that the EuXFEL can be used as an important tool for biomedically relevant research.more » « less
-
Pandey, Suraj; Bean, Richard; Sato, Tokushi; Poudyal, Ishwor; Bielecki, Johan; Cruz_Villarreal, Jorvani; Yefanov, Oleksandr; Mariani, Valerio; White, Thomas A; Kupitz, Christopher; et al (, Nature Methods)
An official website of the United States government
